Selection and maintenance of vertical
cuttings dryer retarder:
1. For the first time, replace the oil after one-cycle operation. And replace
it every 3-6 months later on. If the temperature goes too high or too humid,
remember to shorten the period and to add oil.
2. Retarder is not lubricated when leaving the factory, so users should add
enough lubricating oil until it reaches the designated height by oil
standard.
3. When impact load is too much or startup too frequent, users should
accesorize positioning pin or hydraulic coupling between base and footing, or
demand a positioning slot or positioning plane upon the base.
4. Users should make it clear when placing the order if retarder output shaft
should be installed upwards and negotiate over designing lubricating system.
5. Horizontal and lateral retarder should be installed about 15°
inclined.
6. Vertical and luffing retarders adopt pump reciprocating lubrication. When
input power is
7. It is regulated that retarder should use N220 industrial gear
oil(horizontal one uses N150 gear oil), lubricating oil should comply with.
8. After installation, the input shaft of retarder should be rotated flexibly
by hand and output shaft rotated by 360°, the resistance felt everywhere should
be the same, and lubricating oil should be added to the designated height by oil
standard. Then, connect the power to allow it run without load for 1-2 hours and
increase load bit by bit if everything is alright.